This HP test equipment accessory allows the user to add triggering on composite video signals to analog or digital scopes, spectrum analysers or other signal monitoring equipment.
Of course this was back in the days of composite ANALOG video signals
The manual specifically discusses the use of this accessory with oscilloscopes.
DC restoration is provided and a stable trigger is provided for most international standard broadcast signals (back in the late 80's)
In keeping with the type of signals this accessory was to be used with, the bandwidth is 15Hz to 10Mhz ONLY
Hewlett Packard TV/Video Sync Pod with ORIGINAL Users Guide and Operating Notes
Released to market in the late 1980's
Model: 1133A
Original manual part number: 01133-90901
Pod with manual
NO power module - uses a 20V AC source supply, connection via a molex male at the rear
Comes with the original User guide/Operating notes
Outline of the manual contents:
Key Features
Physical Description
Operating Characteristics
Operation of the Pod - both analog and digital scopes are discussed. vertical gain calibration
Video Signal fundamentals including VITS
Service information INCLUDING block diagram, complete components list and schematics of this accessory
As New - stored for years in a sealed plastic bag