null Skip to main content

HARBUCH Toroidal AC Power Transformer 800VA (2x 40V 2x 15V 4x 10V) NEW Old Stock

Harbuch Electronics

$150.00
SKU:
CHKGUM9290
Condition:
New
Minimum Purchase:
1 unit
Maximum Purchase:
1 unit
Shipping:
Calculated at Checkout

Oh Dear! This item has been sold but take a look around for other similar items

Ex workshop spare parts and R&D/manufacturing stock

ALL components were sourced through reputable local distributors such as RS Electronics, Farnell, WES and Rockby (Victoria) or direct from the manufacturer.

BRAND NEW, Old stock

 

HARBUCH ELECTRONICS - Toroidal Power Transformer

Made in Australia (Sydney)

I suspect Harbuch is going through a period of "transition" as their website appears to be only partially active and I read somewhere that the original owner (Rod) was retiring

Model: PTT-4776

800VA Total power output capable

Label on one side of the core reads:

HARBUCH ELECTRONICS PTY LTD

PTT-4776 800VA

PRIM 240V ORG-ORG

SEC 1: 2x 40V/9.4A RED-YEL & BLU-GRY

SEC 2: 2x 15V/1A GRN-VLT & BLK-WHT

SEC 5,6,7,8 4x 10V/1A BRN/ORG PNK/RED YEL/BLU GRY/GRN

(Old Australian Made "Boomerang" graphic sticker to the right side)

Sextuplet (Fully isolated) secondaries:

2x 40V @ 9.4A full load) - typically for audio power amplifier output stages

2x 15V @ 1A - typically for auxiliary modules, input stages (particularly those based on Op amps with dual rail supplies)

4x 10V @ 1A - more auxiliary supply sources

Orange - Orange: 240V AC Primary winding (not multi-tap, ONLY 240V input)

NOT potted (no epoxy resin infill - this will be a task for the new owner to undertake

NO mounting hardware supplied (rubber or plastic discs, metal disc and central bolt) with any of these transformers.

 

PHYSICAL DIMENSIONS:

160mm diameter

Unfilled "donut" 45mm centre hole

65mm height

All primary & secondary flying leads 200mm length

All leads are solid core, pvc insulation.

WEIGHT:

5.8Kg !!! It's quite a heavy beast!

 

COSMETIC CONDITION:

BRAND NEW

Old Stock

 

TESTING:

To confirm the transformer is functioning properly, I have made some simple "open circuit/no load" voltage tests on transformer

Secondary 1 & 2: 50.8V each

Secondary 3 & 4: 15.4V each

Secondary 5,6,7 & 8: 10.22 ~ 10.18V *** Green/Grey 10V secondary read slightly lower than the other three windings

Confirmed total isolation between Primary & ALL Secondary windings and between ALL secondaries, this is not an Auto-transformer!.

At the conclusion of these simple voltage tests I have now lightly twisted each secondary winding pair together to ease identification later - there are a LOT of colours to deal with!

Take a look around at the current pricing of multiple secondary 800VA toroids (sit down first) and you will see this is a bargain for a new transformer - I have just one available now

BRAND NEW Unused Tested as described in the description